Products
PLC Programmable Controller
SIEMENS SIPLUS S7300 6AG1334-0KE00-7AB0 6AG1314-6EH04-7AB0 6AG1313-6CG04-7AB0 6AG1331-7RD00-2AB0 6AG1322-1BF01-2XB0
  • SIPLUS S7300 CPU314C2DP-3
  • SIPLUS S7300 CPU314C2DP-1
  • SIPLUS S7300 CPU314C2DP-2
SIEMENS SIPLUS S7300 6AG1334-0KE00-7AB0 6AG1314-6EH04-7AB0 6AG1313-6CG04-7AB0 6AG1331-7RD00-2AB0 6AG1322-1BF01-2XB0

Model Number: 6AG1334-0KE00-7AB0 6AG1314-6EH04-7AB0 6AG1313-6CG04-7AB0 6AG1331-7RD00-2AB0 6AG1322-1BF01-2XB0
Category: SIEMENS SIPLUS S7300
Product Type: PLC
Type: Industry Automation
Place of Origin: Made in Germany	
Warranty: 12 month warranty



Download:
Specification:

SIPLUS S7-300 SM 334 4AI 2AQ based on 6ES7334-0KE00-0AB0 with conformal coating, -25…+70 °C, analog module isolated, 4 AI/2 AQ, 12 bit, 0-10 V for Pt100 (climatic range -120-155 degrees) and 10 kOhm measuring range, 1x 20-pole

Product Feature:

SIPLUS S7-300 SM 334 4AI 2AQ based on 6ES7334-0KE00-0AB0 with conformal coating, -25…+70 °C, analog module isolated, 4 AI/2 AQ, 12 bit, 0-10 V for Pt100 (climatic range -120-155 degrees) and 10 kOhm measuring range, 1x 20-pole

Order Code:
Supply voltage
Load voltage L+
● Rated value (DC)
● Reverse polarity protection
24 V
Yes
Input current
from supply and load voltage L+ (without load), max. 80 mA
from backplane bus 5 V DC, max. 60 mA
Power loss
Power loss, typ. 2 W
Analog inputs
Number of analog inputs 4
● For voltage measurement 2
● For resistance measurement 4
permissible input voltage for voltage input (destruction limit), max. 20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)
Constant measurement current for resistance-type transmitter, typ. 490 µA; at PT100 (490 µA), at 10 kOhm (105 µa)
Cycle time (all channels) max. 85 ms
Input ranges
● Voltage Yes
● Current No
● Thermocouple No
● Resistance thermometer Yes
● Resistance Yes
Input ranges (rated values), voltages
● 0 to +10 V
— Input resistance (0 to 10 V)
Yes
100 kΩ
Input ranges (rated values), resistance thermometer
● Pt 100 Yes; only climatic range
Input ranges (rated values), resistors
● 0 to 10000 ohms Yes
Characteristic linearization
● parameterizable
— for resistance thermometer
Yes
Pt100 (climate)
Cable length
● shielded, max. 100 m
Analog outputs
Number of analog outputs 2
Voltage output, short-circuit protection Yes
10 mA
Voltage output, short-circuit current, max.
Output ranges, voltage
● 0 to 10 V Yes
Load impedance (in rated range of output)
● with voltage outputs, min.
● with voltage outputs, capacitive load, max.
2.5 kΩ
1 µF
Cable length
● shielded, max. 100 m
Analog value generation for the inputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.
● Integration time, parameterizable
● Integration time (ms)
● Interference voltage suppression for interference frequency f1 in Hz
12 bit
Yes
16,67 / 20 ms
50 / 60 Hz
Analog value generation for the outputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), max.
● Conversion time (per channel)
12 bit
500 µs
Settling time
● for resistive load
● for capacitive load
0.8 ms
0.8 ms
Encoder
Connection of signal encoders
● for voltage measurement
● for resistance measurement with two-wire connection
● for resistance measurement with three-wire connection
● for resistance measurement with four-wire connection
Yes
Yes
Yes
Yes
Errors/accuracies
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-)
● Resistance, relative to input range, (+/-)
● Resistance thermometer, relative to input range, (+/-
)
● Voltage, relative to output range, (+/-)
0.8 %; 0 to 10V
3.7 %; 10 kOhm
1.1 %
1.1 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-)
● Resistance, relative to input range, (+/-)
● Resistance thermometer, relative to input range, (+/-
)
● Voltage, relative to output range, (+/-)
0.5 %; 0 to 10V
2.8 %; 10 kOhm
0.8 %
0.85 %
Interrupts/diagnostics/status information
Alarms No
Diagnostics function No
Potential separation
Potential separation analog inputs
● between the channels and backplane bus Yes
Potential separation analog outputs
● between the channels
● between the channels and backplane bus
● between the channels and the power supply of the electronics
No
Yes
Yes
Isolation
Isolation tested with 500 V DC
Standards, approvals, certificates
CE mark Yes
UL approval Yes; File E239877
RCM (formerly C-TICK) Yes
KC approval Yes
EAC (formerly Gost-R) Yes
Ambient conditions
Ambient temperature during operation
● min.
● max.
-25 °C; = Tmin
70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use
Ambient temperature during storage/transportation
● min.
● max.
-40 °C
70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max.
● Ambient air temperature-barometric pressure- altitude
5 000 m
Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin
... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin
... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
● With condensation, tested in accordance with IEC 60068-2-38, max. 100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Resistance
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3
— to chemically active substances according to EN 60721-3-3
— to mechanically active substances according to EN 60721-3-3
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Yes; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6
— to chemically active substances according to EN 60721-3-6
— to mechanically active substances according to EN 60721-3-6
Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA- 71.04
Yes; Class 3 (excluding trichlorethylene)
Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 * The supplied plug covers must remain in place over the unused interfaces during operation!
connection method / header
required front connector 20-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 117 mm
Weights
Weight, approx. 200 g


Symbol:
6AG1332-5HB01-2AB0 6AG1313-5BG04-7AB0 6AG1321-1FF10-7AA0
6AG1313-6CG04-2AY0 6AG1331-7NF00-2AB0 6AG1322-1BL00-2AA0
6AG1350-1AH03-2AE0 6AG1314-6CH04-7AB0 6AG1331-7TB00-7AB0
6AG1332-7ND02-4AB0 6AG1341-1CH02-7AE0 6AG1322-1FF01-7AA0
6AG1322-1BH01-2AA0 6AG1314-6CH04-2AY0 6AG1312-5BF04-7AB0
6AG1350-2AH01-4AE0 6AG1321-1FH00-7AA0 6AG1331-7SF00-4AB0
6AG1317-2EK14-7AB0 6AG1314-1AG14-7AB0 6AG1315-2EH14-7AB0
6AG1341-1AH02-7AE0 6AG1322-5FF00-4AB0 6AG1321-7RD00-4AB0
6AG1312-5BF04-2AY0 6AG1334-0KE00-7AB0 6AG1314-6EH04-7AB0
6AG1313-6CG04-7AB0 6AG1331-7RD00-2AB0 6AG1322-1BF01-2XB0
6AG1322-1FH00-7AA0 6AG1315-2EH14-2AY0 6AG1317-2EK14-2AY0
6AG1332-5HF00-2AB0 6AG1321-1FF01-2AA0 6AG1331-7PF11-4AB0
6AG1313-5BG04-2AY0 6AG1321-7BH01-4AS0 6AG1340-1AH02-2AE0
6AG1315-2AH14-7AB0 6AG1332-5HD01-7AB0 6AG1340-1CH02-2AE0
6AG1314-6BH04-7AB0


Contact us
E-mail:info@fitsitech.com
Tel:+86-19928764188 
Add:Shangmei Times, 57 Longguan East Road, Tsinghua Community, Longhua Street, Longhua District, Shenzhen, China

     
Inquiry
Name:
E-mail:
Description:
CopyRight © 2010~2017 Shenzhen Fitsi Technology Co.,LTD All Right Reserved.     Sitemap    粤ICP备14001694号-由万创科技提供技术支持