Products
PLC Programmable Controller
SIEMENS SIMATIC S7-300 CPU Module 6ES7315-2AH14-0AB0 6ES7314-6CH04-0AB0 6ES7314-1AG14-0AB0 6ES7312-5BF04-0AB0 6ES7314-6EH04-4AB2
  • 15783776904_1109016826
  • 10380977874_1109016826
SIEMENS SIMATIC S7-300 CPU Module 6ES7315-2AH14-0AB0 6ES7314-6CH04-0AB0 6ES7314-1AG14-0AB0 6ES7312-5BF04-0AB0 6ES7314-6EH04-4AB2

Model Number: 6ES7315-2AH14-0AB0 6ES7314-6CH04-0AB0 6ES7314-1AG14-0AB0 6ES7312-5BF04-0AB0 6ES7314-6EH04-4AB2
Category: SIEMENS SIMATIC S7-300 CPU
Product Type: CPU
Type: Industry Automation
Place of Origin: Made in Germany	
Warranty: 12 month warranty



Download:
Specification:

SIMATIC S7-300, CPU 315-2DP Central processing unit with MPI Integr. power supply 24 V DC Work memory 256 KB 2nd interface DP master/slave Micro Memory Card required

Product Feature:

SIMATIC S7-300, CPU 315-2DP Central processing unit with MPI Integr. power supply 24 V DC Work memory 256 KB 2nd interface DP master/slave Micro Memory Card required

Order Code:
General information
HW functional status 01
Firmware version V3.3
Product function
● Isochronous mode Yes; For PROFINET only
Engineering with
● Programming package STEP 7 V5.5 or higher with HSP 191
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V 
external protection for power supply lines (recommendation) Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type
B, min. 4 A
Mains buffering
● Mains/voltage failure stored energy time
● Repeat rate, min
5 ms
1 s
Load voltage L+
● Rated value (DC)
● Reverse polarity protection
24 V
Yes
Digital outputs
— Rated value (DC)
— Reverse polarity protection
24 V;
No;
Input current
Current consumption (rated value) 850 mA
Current consumption (in no-load operation), typ. 190 mA
Inrush current, typ. 5 A
I²t 0.7 A²·s
Digital inputs
● from load voltage L+ (without load), max 80 mA
Digital outputs
● from load voltage L+, max. 50 mA
Power loss
Power loss, typ. 14 W
Memory
Work memory
● integrated
● expandable
192 kbyte
No
Load memory
● Plug-in (MMC)
● Plug-in (MMC), max.
● Data management on MMC (after last programming), min.
Yes
8 Mbyte
10 y
Backup
● present
● without battery
Yes; Guaranteed by MMC (maintenance-free)
Yes; Program and data
CPU processing times
for bit operations, typ. 0.06 µs
for word operations, typ. 0.12 µs
for fixed point arithmetic, typ. 0.16 µs
for floating point arithmetic, typ. 0.59 µs
CPU-blocks
Number of blocks (total) 1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
● Number, max.
● Size, max.
1024; Number range: 1 to 16000
64 kbyte
FB
● Number, max.
● Size, max.
1024; Number range: 0 to 7999
64 kbyte
FC
● Number, max.
● Size, max.
1024; Number range: 0 to 7999
64 kbyte
OB
● Number, max.
● Size, max.
● Number of free cycle OBs
● Number of time alarm OBs
● Number of delay alarm OBs
● Number of cyclic interrupt OBs
● Number of process alarm OBs
● Number of DPV1 alarm OBs
● Number of isochronous mode OBs
● Number of technology synchronous alarm OBs
● Number of startup OBs
● Number of asynchronous error OBs
● Number of synchronous error OBs
see instruction list
64 kbyte
1; OB 1
1; OB 10
2; OB 20, 21
4; OB 32, 33, 34, 35
1; OB 40
3; OB 55, 56, 57
1; OB 61; only for PROFINET
1; OB 65
1; OB 100
6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
2; OB 121, 122
Nesting depth
● per priority class
● additional within an error OB
16
4
Counters, timers and their retentivity
S7 counter
● Number 256
Retentivity
— adjustable
— lower limit
— upper limit
— preset
Yes
0
255
No retentivity
Time range
— loer limit
— upper limit
10 ms
9990 s
IEC counter
● present
● Type
● Number
Yes
SFB
Unlimited (limited only by RAM capacity)
S7 times
● Number 512
Retentivity
— adjustable
— lower limit
— upper limit
— preset
Yes 0
511
No retentivity
Time range
— lower limit 10 ms
— upper limit 9 990 s
IEC timer
● present
● Type
● Number
Yes
SFB
Unlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max. 64 kbyte
Flag
● Size, max.
● Retentivity available
● Retentivity preset
● Number of clock memories
256 byte
Yes; From MB 0 to MB 255
MB 0 to MB 15
8; 1 memory byte
Data blocks
● Retentivity adjustable
● Retentivity preset
Yes; via non-retain property on DB
Yes
Local data
● per priority class, max. 32 byte; Max. 2048 bytes per block
Address area
I/O address area
● Inputs
● Outputs
2048 byte
2048 byte
of which distributed
— Inputs
— Outputs
2003 byte
2010 byte
Process image
● Inputs
● Outputs
● Inputs, adjustable
● Outputs, adjustable
● Inputs, default
● Outputs, default
2048 byte
2048 byte
2048 byte
2048 byte
256 byte
256 byte
Default addresses of the integrated channels
— Digital inputs
— Digital outputs
— Analog inputs
— Analog outputs
136.0 to 138.7
136.0 to 137.7
800 to 809
800 to 803
Subprocess images
● Number of subprocess images, max. 1; With PROFINET IO, the length of the user data is limited to 1600 bytes
Digital channels
● Inputs
— of which central
● Outputs
— of which central
16 048
1 016
16096
1008
Analog channels
● Inputs
— of which central
● Outputs
— of which central
1006
253
1007
250
Hardware configuration
Number of expansion units, max. 3
Number of DP masters
● integrated
● via CP
1
4
Number of operable FMs and CPs (recommended)
● FM
● CP, PtP
● CP, LAN
8
8
10
Rack
● Racks, max.
● Modules per rack, max.
4
8; In rack 3 max. 7
Time of day
Clock
● Hardware clock (real-time)
● retentive and synchronizable
● Backup time
● Deviation per day, max.
● Behavior of the clock following POWER-ON
● Behavior of the clock following expiry of backup period
Yes
Yes
6 wk; At 40 °C ambient temperature
10 s; Typ.: 2 s
Clock continues running after POWER OFF

the clock continues at the time of day it had when power was switched offoff
Operating hours counter
● Number 1
● Number/Number range 0
● Range of values 0 to 2^31 hours (when using SFC 101)
● Granularity 1 h
● retentive Yes; Must be restarted at each restart
Clock synchronization
● supported Yes
● to MPI, master Yes
● to MPI, slave Yes
● to DP, master Yes
● to DP, slave Yes; With DP slave only slave clock
● in AS, master Yes
● in AS, slave Yes
● on Ethernet via NTP Yes; As client
Digital inputs
Number of digital inputs 24
● of which inputs usable for technological functions 16
integrated channels (DI)  24
Input characteristic curve in accordance with IEC 61131, Yes
type 1
Number of simultaneously controllable inputs
horizontal installation
— up to 40 °C, max. 24
— up to 60 °C, max. 12
vertical installation
— up to 40 °C, max. 12
Input voltage
● Rated value (DC)
● for signal "0"
● for signal "1"
24 V
-3 to +5V
+15 to +30 V
Input current
● for signal "1", typ. 8 mA
Input delay (for rated value of input voltage)
for standard inputs
— parameterizable Yes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain
circumstances your newly set filter time may not be effective until the next filter cycle.)
— Rated value 3 ms
for technological functions
— at "0" to "1", max. 8 µs; Minimum pulse width/minimum pause between pulses at maximum counting frequency
Cable length
● shielded, max.
● unshielded, max.
1 000 m; 50 m for technological functions
600 m; for technological functions: No
for technological functions
­ shielded, max.
­ unshielded, max.
50 m; at maximum count frequency
not alloed
Digital outputs
Number of digital outputs 16
● of which high-speed outputs 4; Notice: You cannot connect the fast outputs of your CPU in parallel
Functions for technology functions, e.g. high-speed cam switch signals
Short-circuit protection Yes
● Response threshold, typ. 1 A
Limitation of inductive shutdown voltage to L+ (-48 V)
Controlling a digital input Yes
Switching capacity of the outputs
● on lamp load, max. 5 W
Load resistance range
● lower limit
● upper limit
48 Ω
4 kΩ
Output voltage
● for signal "0", max.
● for signal "1", min.
L+ (-0.8 V)
Output current
● for signal "1" rated value
● for signal "1" permissible range, min.
● for signal "1" permissible range, max.
● for signal "1" minimum load current
● for signal "0" residual current, max
0.5 A
5 mA
0.6 A
5 mA
0.5 mA
Parallel switching of two outputs
● for uprating
● for redundant control of a load
No
Yes
Switching frequency
● with resistive load, max.
● with inductive load, max.
● on lamp load, max.
● of the pulse outputs, with resistive load, max
100 Hz
0.5 Hz
100 Hz
2.5 kHz
Total current of the outputs (per group)
horizontal installation
— up to 40 °C, max.
— up to 60 °C, max.
3 A
2 A
all other mounting positions
— up to 40 °C, max. 2 A
Integrated high-speed cams
● Switching accuracy (+/-) 70 µs
Cable length
● shielded, max.
● unshielded, max.
1 000 m
600 m
Number of analog inputs 0
● 2-wire sensor
— permissible quiescent current (2-wire sensor), max.
Yes
1.5 mA
Errors/accuracies
Temperature error (relative to input range), (+/-) 0.006 %/K 
Crosstalk between the inputs, min. 60 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) 0.06%
Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-) 0.10%
Linearity error (relative to output range), (+/-) 0.15%
Temperature error (relative to output range), (+/-) 0.01 %/K
Crosstalk between the outputs, min. 60 dB
Repeat accuracy in steady state at 25 °C (relative to output range), (+/-) 0.06%
Operational error limit in overall temperature range
● Voltage, relative to input range, (+/-)
● Current, relative to input range, (+/-)
● Resistance, relative to input range, (+/-)
● Voltage, relative to output range, (+/-)
● Current, relative to output range, (+/-)
1 %
1 %
1 %
1 %
1 %
Basic error limit (operational limit at 25 °C)
● Voltage, relative to input range, (+/-)
● Current, relative to input range, (+/-)
● Resistance, relative to input range, (+/-)
● Resistance thermometer, relative to input range, (+/-
)
● Voltage, relative to output range, (+/-)
● Current, relative to output range, (+/-)
0.8 %; Linearity error ±0.06 %
0.8 %; Linearity error ±0.06 %
0.8 %; Linearity error ±0.2 %
0.8 %
0.8 %
0.8 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
● Series mode interference (peak value of interference < rated value of input range), min.
● Common mode interference, min.
30 dB

40 dB
Interfaces
Number of industrial Ethernet interfaces 1; 2 ports (switch) RJ45
Number of PROFINET interfaces 1; 2 ports (switch) RJ45
Number of RS 485 interfaces 1; Combined MPI / PROFIBUS DP
Number of RS 422 interfaces 0
1. Interface
Interface type Integrated RS 485 interface
Isolated Yes
Interface types
● RS 485
● Output current of the interface, max.
Yes
200 mA
Protocols
● MPI
● PROFIBUS DP master
● PROFIBUS DP slave
● Point-to-point connection
Yes
Yes
Yes
No
MPI
● Transmission rate, max. 12 Mbit/s
Services
— PG/OP communication
— Routing
— Global data communication
— S7 basic communication
— S7 communication
— S7 communication, as client
— S7 communication, as server
Yes
Yes
Yes
Yes
Yes
No; but via CP and loadable FB
Yes
PROFIBUS DP master
● Transmission rate, max.
● Number of DP slaves, max.
12 Mbit/s
124
Services
— PG/OP communication
— Routing
— Global data communication
— S7 basic communication
— S7 communication
— S7 communication, as client
— S7 communication, as server
— Equidistance
— Isochronous mode
— SYNC/FREEZE
— Activation/deactivation of DP slaves
— Number of DP slaves that can be simultaneously activated/deactivated, max.
— Direct data exchange (slave-to-slave communication)
— DPV1
Yes
Yes
No
Yes; I blocks only
Yes
No
Yes
Yes
No
Yes
Yes
8
Yes; as subscriber
Yes
Address area
— Inputs, max.
— Outputs, max.
2 kbyte
2 kbyte
User data per DP slave
— Inputs, max.
— Outputs, max.
244 byte
244 byte
PROFIBUS DP slave
● Transmission rate, max.
● automatic baud rate search
● Address area, max.
● User data per address area, max.
12 Mbit/s
Yes; only with passive interface
32
32 byte
Services
— PG/OP communication
— Routing
— Global data communication
— S7 basic communication
— S7 communication
— S7 communication, as client
Yes
Yes; Only with active interface
No
No
Yes
No
— S7 communication, as server
— Direct data exchange (slave-to-slave communication)
— DPV1
Yes; Connection configured on one side only
Yes
No
Transfer memory
— Inputs
— Outputs
244 byte
244 byte
2. Interface
Interface type PROFINET
Isolated Yes
automatic detection of transmission rate Yes; 10/100 Mbit/s
Autonegotiation Yes
Autocrossing Yes
Change of IP address at runtime, supported Yes
Interface types
● RJ 45 (Ethernet)
● Number of ports
● integrated switch
Yes
2
Yes
Protocols
● MPI
● PROFINET IO Controller
● PROFINET IO Device
● PROFINET CBA
● PROFIBUS DP master
● PROFIBUS DP slave
● Open IE communication
● Web server
● Media redundancy
No
Yes; Also simultaneously with IO-Device functionality
Yes; Also simultaneously with IO Controller functionality
Yes
No
No
Yes; Via TCP/IP, ISO on TCP, and UDP
Yes
Yes
PROFINET IO Controller
● Transmission rate, max. 100 Mbit/s
Services
— PG/OP communication
— Routing
— S7 communication
— Isochronous mode
— IRT
— Shared device
— Prioritized startup
— Number of IO devices with prioritized startup, max.
— Number of connectable IO Devices, max.
— Of which IO devices with IRT, max.
— of which in line, max.
— Number of IO Devices with IRT and the option "high flexibility"
— of which in line, max.
— Number of connectable IO Devices for RT, max.
— of which in line, max.
— Activation/deactivation of IO Devices
— Number of IO Devices that can be simultaneously activated/deactivated, max.
— IO Devices changing during operation (partner ports), supported
— Number of IO Devices per tool, max.
— Device replacement without swap medium
— Send cycles
— Updating time
Yes
Yes
Yes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32
Yes; OB 61
Yes
Yes
Yes
32
128
64
64
128
61
128
128
Yes
8
Yes
8
Yes
250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
250 µs to 512 ms (depending on the operating mode, see Manual "S7- 300 CPU 31xC and CPU 31x, technical Data" for more details)
Address area
— Inputs, max.
— Outputs, max.
— User data consistency, max.
2 kbyte
2 kbyte
1 024 byte
PROFINET IO Device
Services
— PG/OP communication
— Routing
— S7 communication
— Isochronous mode
— IRT
— PROFIenergy
— Shared device
— Number of IO Controllers with shared device, max.
Yes
Yes
Yes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32
No
Yes
Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device
Yes
2
Transfer memory
— Inputs, max.
— Outputs, max.
1 440 byte; Per IO Controller with shared device
1 440 byte; Per IO Controller with shared device
Submodules
— Number, max.
— User data per submodule, max.
64
1 024 byte
PROFINET CBA
● acyclic transmission
● cyclic transmission
Yes
Yes
Open IE communication
● Number of connections, max.
● Local port numbers used at the system end
● Keep-alive function, supported
8
0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964,
65532, 65533, 65534, 65535
Yes
Protocols
PROFIsafe No
Redundancy mode
Media redundancy
— Switchover time on line break, typ.
— Number of stations in the ring, max.
200 ms; PROFINET MRP
50
Open IE communication
● TCP/IP
— Number of connections, max.
— Data length for connection type 01H, max.
— Data length for connection type 11H, max.
— several passive connections per port, supported
● ISO-on-TCP (RFC1006)
— Number of connections, max.
— Data length, max.
● UDP
— Number of connections, max.
— Data length, max.
Yes; via integrated PROFINET interface and loadable FBs
8
1 460 byte
32 768 byte
Yes
Yes; via integrated PROFINET interface and loadable FBs
8
32 768 byte
Yes; via integrated PROFINET interface and loadable FBs
8
1 472 byte
Web server
● supported
● User-defined websites
● Number of HTTP clients
Yes
Yes
5
communication functions / header
PG/OP communication Yes
Data record routing Yes
Global data communication
● supported
● Number of GD loops, max.
● Number of GD packets, max.
● Number of GD packets, transmitter, max.
Yes
8
8
8
● Number of GD packets, receiver, max.
● Size of GD packets, max.
● Size of GD packet (of which consistent), max.
8
22 byte
22 byte
S7 basic communication
● supported
● User data per job, max.
● User data per job (of which consistent), max.
Yes
76 byte
76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
● supported
● as server
● as client
● User data per job, max.
Yes
Yes
Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5 compatible communication
● supported Yes; via CP and loadable FC
communication functions / PROFINET CBA (with set target communication load) / header
● Setpoint for the CPU communication load
● number of remote connection partners / with PROFINET CBA
● number of technological functions / with PROFINET CBA / for master or slave
● number of connections / with PROFINET CBA / for master or slave / total
● data volume / of the input variables / with PROFINET CBA / for master or slave
● data volume / of the output variables / with PROFINET CBA / for master or slave
● number of internal and PROFIBUS interconnections
/ with PROFINET CBA / maximum
● data volume / of internal and PROFIBUS interconnections / with PROFINET CBA / for master or slave
● data volume / with PROFINET CBA / per connection
/ maximum
50 %
32

30

1 000

4 000 byte

4 000 byte

500


4 000 byte

1 400 byte
performance data / PROFINET CBA / remote interconnection / with acyclic transfer / header
— update time / of the remote interconnections / in the case of acyclic transmission / with PROFINET CBA
— number of remote connections to input variables / in the case of acyclic transmission / with PROFINET CBA / maximum
— number of remote connections to output variables / in the case of acyclic transmission / with PROFINET CBA / maximum
— data volume / as user data for remote interconnections with input variables / in the case of acyclic transmission / with PROFINET CBA
— data volume / as user data for remote interconnections with output variables / in the case of acyclic transmission / with PROFINET CBA
— data volume / as user data for remote interconnections / in the case of acyclic transmission / with PROFINET CBA / per connection / maximum
500 ms


100


100


2 000 byte


2 000 byte


1 400 byte
performance data / PROFINET CBA / remote interconnection / with cyclic transfer / header
— update time / of the remote interconnections / with cyclical transfer / with PROFINET CBA
— number of remote connections to input variables / with PROFINET CBA / with cyclic transfer / maximum
— number of remote connections to output variables / with cyclical transfer / with PROFINET CBA / maximum
— data volume / as user data for remote interconnections with input variables / with cyclical
10 ms

200

200


2 000 byte
transfer / with PROFINET CBA / maximum
— data volume / as user data for remote interconnections with output variables / with cyclical transfer / with PROFINET CBA / maximum
— data volume / as user data for remote interconnections / with cyclical transfer / with PROFINET CBA / per connection / maximum
2 000 byte


450 byte
performance data / PROFINET CBA / HMI variables via PROFINET / acyclic / header
— number of connectable HMI stations / for HMI variables / in the case of acyclic transmission / with PROFINET CBA
— update time / of the HMI variables / in the case of acyclic transmission / with PROFINET CBA
— number of HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum
— data volume / as user data for HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum
3; 2x PN OPC/1x iMap


500 ms

200

2 000 byte
performance data / PROFINET CBA / PROFIBUS proxy functionality / header
— product function / with PROFINET CBA / PROFIBUS proxy functionality
— number of coupled PROFIBUS devices / with PROFIBUS functionality
— data volume / with PROFIBUS proxy functionality / with PROFINET CBA / per connection / maximum
Yes

16

240 byte; Slave-dependent
Number of connections
● overall
● usable for PG communication
— reserved for PG communication
— adjustable for PG communication, min.
— adjustable for PG communication, max.
● usable for OP communication
— reserved for OP communication
— adjustable for OP communication, min.
— adjustable for OP communication, max.
● usable for S7 basic communication
— reserved for S7 basic communication
— adjustable for S7 basic communication, min.
— adjustable for S7 basic communication, max.
● usable for S7 communication
— reserved for S7 communication
— adjustable for S7 communication, min.
— adjustable for S7 communication, max.
● total number of instances, max.
● usable for routing
12
11
1
1
11
11
1
1
11
8
0
0
8
10
0
0
10
32
X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.
S7 message functions
Number of login stations for message functions, max. 12; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messages Yes
simultaneously active Alarm-S blocks, max. 300
Test commissioning functions
Status block Yes; Up to 2 simultaneously 
Single step Yes
Number of breakpoints 4
Status/control
● Status/control variable
● Variables
● Number of variables, max.
— of which status variables, max.
— of which control variables, max.
Yes
Inputs, outputs, memory bits, DB, times, counters
30
30
14
Forcing
● Forcing
● Forcing, variables
● Number of variables, max.
Yes
Inputs, outputs
10
Diagnostic buffer
● present
● Number of entries, max.
— adjustable
— of which powerfail-proof
● Number of entries readable in RUN, max.
— adjustable
— preset
Yes
500
No
100; Only the last 100 entries are retained 499
Yes; From 10 to 499
10
Service data
● can be read out Yes
Interrupts/diagnostics/status information
Diagnostics indication LED
● Status indicator digital input (green)
● Status indicator digital output (green)
Yes
Yes
Integrated Functions
Counter
● Number of counters
● Counting frequency, max.

4; See "Technological Functions" manual
60 kHz
Frequency measurement
● Number of frequency meters
Yes
4; up to 60 kHz (see "Technological Functions" manual)
controlled positioning Yes
integrated function blocks (closed-loop control) Yes; PID controller (see "Technological Functions" manual)
PID controller Yes
Number of pulse outputs 4; Pulse width modulation up to 2.5 kHz (see "Technological Functions"
Manual)
Limit frequency (pulse) 2.5 kHz
Potential separation
Potential separation digital inputs
● Potential separation digital inputs
● between the channels
● between the channels and backplane bus
Yes
No
YesYes
Potential separation digital outputs
● Potential separation digital outputs
● between the channels
● between the channels, in groups of
● between the channels and backplane bus
Yes
Yes
8
Yes
Potential separation analog inputs
● Potential separation analog inputs
● between the channels
● between the channels and backplane bus
Yes; common for analog I/O
No
Yes
Potential separation analog outputs
● Potential separation analog outputs
● between the channels
● between the channels and backplane bus
Yes; common for analog I/O
No
Yes
Isolation
Isolation tested with 600 V DC
Ambient conditions
Ambient temperature during operation
● min.
● max.
0 °C
60 °C
configuration / header
Configuration software
● STEP 7 Yes; V5.5 or higher
configuration / programming / header
● Command set
● Nesting levels
see instruction list
8
● System functions (SFC)
● System function blocks (SFB)
see instruction list
see instruction list
Programming language
— LAD
— FBD
— STL
— SCL
— CFC
— GRAPH
— HiGraph®
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Know-how protection
● User program protection/password protection
● Block encryption
Yes
Yes; With S7 block Privacy
Dimensions
Width 120 mm
Height 125 mm
Depth 130 mm
Weights
Weight, approx. 730 g


Symbol:
6ES7314-6EH04-0AB0 6ES7313-6BG04-0AB0 6ES7318-3EL01-0AB0
6ES7317-2EK14-0AB0 6ES7317-2AK14-0AB0 6ES7315-2EH14-0AB0
6ES7313-6CG04-0AB0 6ES7314-6BH04-0AB0 6ES7312-1AE14-0AB0
6ES7313-5BG04-0AB0 6ES7315-2AH14-0AB0 6ES7314-6CH04-0AB0
6ES7314-1AG14-0AB0 6ES7312-5BF04-0AB0 6ES7314-6EH04-4AB2
6ES7313-6CG04-4AB2 6ES7314-6CH04-4AB1 6ES7313-5BG04-4AB1
6ES7315-2EH14-0AB0 6ES7313-5BG04-4AB2 6ES7317-2EK14-0AB0
6ES7314-1AG14-0AB0 6ES7314-6CH04-4AB2 6ES7313-6CG04-4AB1
6ES7314-6EH04-4AB1 6ES7312-1AE14-0AB0 6ES7312-5BF04-0AB0
6ES7313-5BG04-4AB1 6ES7313-5BG04-4AB2 6ES7313-6BG04-0AB0
6ES7313-6CG04-4AB1 6ES7313-6CG04-4AB2 6ES7314-1AG14-0AB0
6ES7314-6BH04-0AB0 6ES7314-6CH04-4AB1 6ES7314-6CH04-4AB2
6ES7314-6EH04-4AB1 6ES7314-6EH04-4AB2 6ES7315-2AH14-0AB0
6ES7315-2EH14-0AB0 6ES7317-2AK14-0AB0 6ES7317-2EK14-0AB0
6ES7318-3EL01-0AB0


Contact us
E-mail:info@fitsitech.com
Tel:+86-19928764188 
Add:Shangmei Times, 57 Longguan East Road, Tsinghua Community, Longhua Street, Longhua District, Shenzhen, China

     
Inquiry
Name:
E-mail:
Description:
CopyRight © 2010~2017 Shenzhen Fitsi Technology Co.,LTD All Right Reserved.     Sitemap    粤ICP备14001694号-由万创科技提供技术支持