Specification:

SIMATIC S7-200 SMART, CPU CR60, compact CPU, AC/DC/relay, onboard I/O: 36 DI 24 V DC; 24 DO relay 2A; Power supply: AC 85-264 V AC at 47-63 Hz, Program/data memory 20 KB

Product Feature:

SIMATIC S7-200 SMART, CPU CR60, compact CPU, AC/DC/relay, onboard I/O: 36 DI 24 V DC; 24 DO relay 2A; Power supply: AC 85-264 V AC at 47-63 Hz, Program/data memory 20 KB

Order Code:
General information
Product type designation CPU CR60 AC/DC/Relay
Engineering with
● Programming package STEP 7 Micro/WIN SMART
Installation type/mounting
Rail mounting Yes; Standard - DIN rail
Supply voltage
Rated value (AC)
● 120 V AC
● 230 V AC

Yes
Yes
permissible range, lower limit (AC) 85 V
permissible range, upper limit (AC) 264 V
Line frequency
● permissible range, lower limit
● permissible range, upper limit
47 Hz
63 Hz
Input current
Current consumption (rated value) 160 mA; at 240 V AC
Current consumption, max. 280 mA; At 120 V AC
Inrush current, max. 7.3 A; at 264 V
Output current
Current output, max. 300 mA; 24 V DC Sensor Power
Power loss
Power loss, max. 20 W
Memory
Type of memory DDR
Flash Yes 
RAM Yes
Memory available for user data 8 kbyte
Memory size 12 kbyte; Program memory
Micro Memory Card Yes; microSDHC Card (optional)
CPU processing times
for bit operations, typ. 150 ns; / instruction
for word operations, typ. 1.2 µs; / instruction
for floating point arithmetic, typ. 3.6 µs; / instruction
Address area
I/O address area
● Inputs
● Outputs
32 byte; Digital inputs
32 byte; Digital outputs
Time of day
Clock
● Type
● Hardware clock (real-time)
● Backup time
● Deviation per day, max.
Hardware clock, no battery backup Yes
7 d
4 s; within 120s/month at 25 °C
Digital inputs
Number of digital inputs 36
Input voltage
● Type of input voltage
● Rated value (DC)
● for signal "0"
● for signal "1"
DC
24 V
< 5 V DC
+15 to +30 V
Input current
● for signal "1", typ. 4 mA
Cable length
● shielded, max.
● unshielded, max.
500 m; 50m shielded for HSC inputs
300 m
Digital outputs
Number of digital outputs 24; Relays
Switching capacity of the outputs
● with resistive load, max.
● on lamp load, max.
2 A
30 W; 30 W with DC, 200 W with AC
Relay outputs
● Number of relay outputs 24
Cable length
● shielded, max.
● unshielded, max.
500 m
150 m
Interfaces
Number of industrial Ethernet interfaces 1
Number of RS 485 interfaces 1
1. Interface
Interface type Ethernet
Isolated Yes; Transformer isolated, 1,500V AC
automatic detection of transmission rate Yes; 10/100 Mbit/s
Autonegotiation Yes
Autocrossing Yes
Interface types
● RJ 45 (Ethernet) Yes
2. Interface
Interface type RS 485 (max. 187.5 kbps)
Protocols
Supports protocol for PROFINET IO Yes
PROFIBUS No
Protocols (Ethernet)
● TCP/IP Yes
communication functions / header
S7 communication
● supported
● as server
● as client
Yes
Yes
Yes
Test commissioning functions
Forcing
● Forcing Yes
Integrated Functions
Counter
● Number of counters

4; 4 at 100 kHz single phase or 2 at 50 kHz A/B phase
PID controller Yes; PID closed-loop control function: Continuous controller outputs, binary controller outputs, automatic/manual mode, max. 8 loops
EMC
Interference immunity against discharge of static electricity
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2
— Test voltage at air discharge
— Test voltage at contact discharge

Yes
8 kV
4 kV
Interference immunity against high-frequency electromagnetic fields
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-3 Yes; 10 V/m, 80 to 1 000 MHz (to IEC 61000-4-3); 10 V/m, 900 MHz,
1.89 GHz, 50% ED (to IEC 61000-4-3)
Interference immunity to cable-borne interference
● Interference immunity on supply lines acc. to IEC 61000-4-4
● Interference immunity on signal cables acc. to IEC 61000-4-4
Yes; 2 kV acc. to IEC 61000-4-4, burst

Yes; ±2 kV acc. to IEC 61000-4-4, Burst
Interference immunity against conducted variable disturbance induced by high-frequency fields
● Interference immunity against high frequency current feed acc. to IEC 61000-4-6 Yes; 10 V, 150 kHz to 80 MHz (to IEC 61000-4-6)
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes; EN 61000-6-4, interference emission: Intended for use in industrial areas.
Emission of conducted and non-conducted interference
● Interference emission via line/AC current cables EN 61000-6-4, interference emission: Intended for use in industrial areas.
Degree and class of protection
IP degree of protection IP20
Ambient conditions
Free fall
● Fall height, max. 0.3 m; five times, in product package
Ambient temperature during operation
● min.
● max.
● horizontal installation, min.
● horizontal installation, max.
● vertical installation, min.
● vertical installation, max.
0 °C
55 °C
0 °C
55 °C
0 °C
45 °C
Ambient temperature during storage/transportation
● min.
● max.
-40 °C
70 °C
Air pressure acc. to IEC 60068-2-13
● Storage/transport, min.
● Storage/transport, max.
660 hPa
1 080 hPa
Altitude during operation relating to sea level
● Installation altitude, min.
● Installation altitude, max.
-1 000 m
2 000 m
Relative humidity
● Operation at 25 ℃ without condensation, max. 95 %
configuration / header
configuration / programming / header
Programming language
— LAD
— FBD
— STL
Yes
Yes
Yes
Dimensions
Width 175 mm
Height 81 mm
Depth 81 mm
Weights
Weight, approx. 620 g


Symbol:
6ES7288-1CR20-0AA1 6ES7288-1CR40-0AA1 6ES7288-1ST20-0AA0
6ES7288-1ST30-0AA0 6ES7288-1ST40-0AA0 6ES7288-1ST60-0AA0
6ES7288-1CR40-0AA0 6ES7288-1CR60-0AA0 6ES7288-1SR40-0AA0
6ES7288-1SR60-0AA0 6ES7288-1SR20-0AA0 6ES7288-1SR30-0AA0
6ES7288-1ST20-0AA1 6ES7288-1ST60-0AA1 6ES7288-1ST40-0AA1
6ES7288-1SR60-0AA1 6ES7288-1SR30-0AA1 6ES7288-1SR20-0AA1
6ES7288-1SR40-0AA1 6ES7288-1ST30-0AA1 6ES7288-1SR20-0AA1
6ES7288-5DT04-0AA0 6ES7288-5BA01-0AA0 6ES7288-1ST20-0AA0
6ES7288-1ST60-0AA0 6ES7288-1SR40-0AA0 6ES7288-1SR30-0AA0
6ES7288-1SR20-0AA0 6ES7288-5AQ01-0AA0 6ES7288-1ST40-0AA0
6ES7288-1ST30-0AA0 6ES7288-1CR40-0AA0 6ES7288-1SR60-0AA0
6ES7288-1CR60-0AA1 6ES7288-5AE01-0AA0 6ES7288-1CR60-0AA0
6ES7288-1CR30-0AA1 6ES7288-6EC01-0AA0 6ES7288-5CM01-0AA0
6ES7288-5DT04-0AA0 6ES7288-5AE01-0AA0 6ES7288-5AQ01-0AA0
6ES7288-5BA01-0AA0


Contact us
E-mail:info@fitsitech.com
Tel:+86-19928764188 
Add:Shangmei Times, 57 Longguan East Road, Tsinghua Community, Longhua Street, Longhua District, Shenzhen, China

     
Inquiry
Name:
E-mail:
Description:
CopyRight © 2010~2017 Shenzhen Fitsi Technology Co.,LTD All Right Reserved.     Sitemap    粤ICP备14001694号-由万创科技提供技术支持