Products
Other Series
HFC Series Parallel Open/Close Style Air Gripper HFCY40 HFCY50 HFCY63 HFCX16 HFCX20 HFCX25 HFCX32 HFCX40 HFCX50 HFCX63
  • HFC80X50-2
  • HFC80X50-3
  • HFC80X50-4
HFC Series Parallel Open/Close Style Air Gripper HFCY40 HFCY50 HFCY63 HFCX16 HFCX20 HFCX25 HFCX32 HFCX40 HFCX50 HFCX63

Product Name: HFCX HFCY Series Parallel Open/Close Style Air Gripper
Product Model: HFCY40 HFCY50 HFCY63 HFCX16 HFCX20 HFCX25 HFCX32 HFCX40 HFCX50 HFCX63
Valve Type: Air Gripper
Brand: AirTAC
Fluid: Air
Acting Type: Double Acting



Download:
Specification:

Specification:

Bore size: 16 20 25 32 40 50 63
Acting type: Double Acting
Fluid:
Air(to be filtered by 40μm filter element)
Operating Pressure: 0.15~0.6MPa(28~87psi)(2.0~6.0bar) 0.15~0.6MPa(22~78psi)(1.5~6.0bar)
Temperature(℃): -10~60
Repeatability mm: ±0.01
Lubrication: Not Required
Max Frequency: 120(c.p.m) 60(c.p.m)
Sensor Switches: DS1-H, DS1-HL
Port Size: M3X0.5 M5X0.8


Product Feature:

1. Cuniform block is adopted in the interior of the air gripper to afford larger gripper force.

2. The bumper is adopted in the front of piston, which can reduce the noise of metal bump.

3. A positioning hole is attached to the bottom of the body, which can improve the  precision and  the consistency  of repeated dismounting and  positioning.

4. Precision repeating snatch which adopted roboticized equipment. 


Installation & Usage:
1. Due to the abrupt changes, the circuit pressure is low, which will lead to the decrease of the gripping force and falling of the work-pieces. In order to avoid the harm to the human body and damage to the equipment, anti-dropping device must be equipped. 

2. Don't use the air gripper under strong external force and impact force.

3. When install and fix  the air gripper, avoid falling down, collision and damage.

4. When fixing  the gripping jaw parts, don't twist  the gripping jaw.

5. There are several kinds of installation method, and the locking torgue of fastening screw must be within the prescribed torque range shown in the below chart. If the locking torque is too large, it will cause the dysfunctional. If the locking torque is too small, it  will cause the position deviation and fall.




Order Code:

2016022754262585.jpg

Symbol:
HFR.jpg
Contact us
E-mail:info@fitsitech.com
Tel:+86-19928764188 
Add:Shangmei Times, 57 Longguan East Road, Tsinghua Community, Longhua Street, Longhua District, Shenzhen, China

     
Inquiry
Name:
E-mail:
Description:
CopyRight © 2010~2017 Shenzhen Fitsi Technology Co.,LTD All Right Reserved.     Sitemap    粤ICP备14001694号-由万创科技提供技术支持