Product Name:2V Series Flow Control Valve Product Model:2V025-06 2V025-08 2V130-10 2V130-15 2V250-20 2V250-25 Valve Type:Normally Closed Valves Brand:AirTAC Fluid: Air, Water,Oil Viscosity limit:Under 20CST
Model: | 2V025-06 | 2V025-08 | 2V130-10 | 2V130-15 | 2V250-20 | 2V250-25 |
Fluid: | Air、Water、Oil | |||||
Acting: | Direct Acting |
Internal Piloted Acting |
||||
Type: | Normally Closed | |||||
Orifice Size(Φmm): |
2.5 |
2.5 | 13.0 | 13.0 | 25.0 | 25.0 |
Cv Valve: |
0.23 |
0.23 | 6.20 | 6.20 | 13.0 | 13.0 |
Port Size: |
PT1/8 |
PT1/4 | PT3/8 | PT1/2 | PT3/4 | PT1 |
Viscosity Limit: | Under 20CST | |||||
Pressure Range: | 0~1.0MPa(0~145psi) | 0.05~1.0MPa(7~145psi) | ||||
Proof Pressure: | 1.5MPa(215psi) | |||||
Material of Body: | Brass With Zinc Plated | Brass | ||||
Seal Material: | VITON | NBR | ||||
Min Activating Time Sec: | 0.05 Sec and Below |
① PT thread,NPT thread and G thread are available.
Specification of coil:
Valve Type: | Power Type: | Frequency(Hz) | Voltage Range | Eletrical Entry | Power Consumption(VA/W) | Insulation | Temperature Rise(℃) |
2V025 2V130 2V250 |
AC | 50 | ±15% |
Terminal Gormmet |
7.0VA | Class B | 35 |
60 | |||||||
DC | - | ±10% | 7.0W | 45 |
2V025 series:
1.Direct acting and normally closed type 2/2 way solenoid valve. Its high sensitivity allows it to change direction quickly.
2.The structure is small and compact.
3.The valve body is made of brass which is heat resistance and the coil conforms to Class B classification. The seals are made of fluorine rubber (VITON) which is suitable for several types of working medium.
2V130 and 250 series:
1.This 2/2 way diaphragm piloted solenoid valve has low energy consumption and large air flow.
2.The starting pressure is low and the operational differential pressure is<0.05MPa.
3.The valve body is made of brass which is heat resistance and the coil conforms to Class B classification . The seals are made of NBR.
Installation & Usage:
1.Check whether the components have been damaged during transportation before installing and using.
2.Pay attention to whether the flow direction of air (notice “→” direction) and thread type are correct.
3.Please notice whether installation condition accords with technical requirements (such as “working pressure” and “applied temperature range”);
4.Take measure to avoid vibration and frozen.
5.Before using the fittings and tubes make sure they are clean. When connecting tofittings, be sure the PTFE Thread Seal Tape is used correctly.
6.Keep the dust away. The dust cover shall be installed in intake and outlet when the device is dismantled and stored.
2V02506A | 2V02508A | 2V13010A | 2V13015A | 2V25020A | 2V25025A |
2V02506B | 2V02508B | 2V13010B | 2V13015B | 2V25020B | 2V25025B |