产品中心
PLC可编程控制器
西门子SIPLUS S7300 6AG1322-1BL00-2AA0 6AG1350-1AH03-2AE0 6AG1314-6CH04-7AB0 6AG1331-7TB00-7AB0 6AG1332-7ND02-4AB0
  • SIPLUS S7300 CPU314C2DP-3
  • SIPLUS S7300 CPU314C2DP-1
  • SIPLUS S7300 CPU314C2DP-2
西门子SIPLUS S7300 6AG1322-1BL00-2AA0 6AG1350-1AH03-2AE0 6AG1314-6CH04-7AB0 6AG1331-7TB00-7AB0 6AG1332-7ND02-4AB0

品牌:SIEMENS/西门子
系列:西门子SIPLUS S7300
型号:6AG1322-1BL00-2AA0 6AG1350-1AH03-2AE0 6AG1314-6CH04-7AB0 6AG1331-7TB00-7AB0 6AG1332-7ND02-4AB0
工作电压:24V



下载:
产品规格:

产品特征:

SIPLUS S7-300 SM 322 32DQ 40-pole based on 6ES7322-1BL00-0AA0 with conformal coating, -25…+70 °C, digital output isolated, 32 DQ, 24 V DC, 0.5 A, 1x 40-pole, total current 4 A/group (16 A/module)

订购码:
Supply voltage
Load voltage L+
● Rated value (DC)
● permissible range, lower limit (DC)
● permissible range, upper limit (DC)
24 V
20.4 V
28.8 V
Input current
from load voltage L+ (without load), max. 160 mA
from backplane bus 5 V DC, max. 110 mA
Power loss
Power loss, typ. 6.6 W
Digital outputs
Number of digital outputs 32
Short-circuit protection Yes; Electronic
● Response threshold, typ. 1 A
Limitation of inductive shutdown voltage to L+ (-53 V)
Controlling a digital input Yes
Switching capacity of the outputs
● on lamp load, max. 5 W
Load resistance range
● lower limit
● upper limit
48 Ω
4 kΩ
Output voltage
● for signal "1", min. L+ (-0.8 V)
Output current
● for signal "1" rated value 0.5 A
● for signal "1" permissible range for 0 to 40 °C, min. 5 mA
● for signal "1" permissible range for 0 to 40 °C, max. 0.6 A
● for signal "1" permissible range for 40 to 60 °C, min. 5 mA
● for signal "1" permissible range for 40 to 60 °C, max. 0.6 A
● for signal "1" minimum load current 5 mA
● for signal "0" residual current, max. 0.5 mA
Output delay with resistive load
● "0" to "1", max.
● "1" to "0", max.
100 µs
500 µs
Parallel switching of two outputs
● for uprating
● for redundant control of a load
No
Yes; only outputs of the same group
Switching frequency
● with resistive load, max.
● with inductive load (acc. to IEC 60947-5-1, DC13), max.
● on lamp load, max.
100 Hz
0.5 Hz
10 Hz
Total current of the outputs (per group)
horizontal installation
— up to 40 °C, max.
— up to 60 °C, max.
— up to 70 °C, max.
4 A
3 A
2 A
vertical installation
— up to 40 °C, max. 2 A
Cable length
● shielded, max.
● unshielded, max.
1 000 m
600 m
Interrupts/diagnostics/status information
Alarms No
Diagnostics function No
Alarms
● Diagnostic alarm No
Diagnoses
● Diagnostic information readable
● Wire-break
● Short-circuit
● missing load voltage
No
No
No
No
Diagnostics indication LED
● Rated load voltage PWR (green)
● Fuse OK FSG (green)
● Group error SF (red)
● Status indicator digital output (green)
● Channel fault indicator F (red)
No
No
No
Yes; per channel
No
Potential separation
Potential separation digital outputs
● between the channels
● between the channels, in groups of
● between the channels and backplane bus
Yes
8
Yes; Optocoupler
Isolation
Isolation tested with 500 V DC
Standards, approvals, certificates
CE mark Yes
UL approval Yes; File E239877
RCM (formerly C-TICK) Yes
KC approval Yes
EAC (formerly Gost-R) Yes
Railway application
● EN 50155 Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B, EN 50155:2007 (see SIOS entry 109755985)
Ambient conditions
Ambient temperature during operation
● min.
● max.
-25 °C; = Tmin
70 °C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 ... +55 °C (T1) or 60 °C @ UL/ULhaz/ATEX/FM use applies
Ambient temperature during storage/transportation
● min.
● max.
-40 °C
70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max.
● Ambient air temperature-barometric pressure- altitude
5 000 m
Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin
... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin
... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
● With condensation, tested in accordance with IEC 60068-2-38, max. 100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Resistance
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3
— to chemically active substances according to EN 60721-3-3
— to mechanically active substances according to EN 60721-3-3
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Yes; Class 3S4 incl. sand, dust, *
Use on land craft, rail vehicles and special-purpose vehicles
— to biologically active substances according to EN 60721-3-5
— to chemically active substances according to EN 60721-3-5
— to mechanically active substances according to EN 60721-3-5
Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request
Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 50155 (ST2); *
Yes; Class 5S3 incl. sand, dust; *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6
— to chemically active substances according to EN 60721-3-6
— to mechanically active substances according to EN 60721-3-6
Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Yes; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA- 71.04
Yes; Class 3 (excluding trichlorethylene)
Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 * The supplied plug covers must remain in place over the unused interfaces during operation!
connection method / header
required front connector 40-pin
Dimensions
Width 40 mm
Height 125 mm
Depth 120 mm
Weights
Weight, approx. 260 g


标记:
6AG1332-5HB01-2AB0 6AG1313-5BG04-7AB0 6AG1321-1FF10-7AA0
6AG1313-6CG04-2AY0 6AG1331-7NF00-2AB0 6AG1322-1BL00-2AA0
6AG1350-1AH03-2AE0 6AG1314-6CH04-7AB0 6AG1331-7TB00-7AB0
6AG1332-7ND02-4AB0 6AG1341-1CH02-7AE0 6AG1322-1FF01-7AA0
6AG1322-1BH01-2AA0 6AG1314-6CH04-2AY0 6AG1312-5BF04-7AB0
6AG1350-2AH01-4AE0 6AG1321-1FH00-7AA0 6AG1331-7SF00-4AB0
6AG1317-2EK14-7AB0 6AG1314-1AG14-7AB0 6AG1315-2EH14-7AB0
6AG1341-1AH02-7AE0 6AG1322-5FF00-4AB0 6AG1321-7RD00-4AB0
6AG1312-5BF04-2AY0 6AG1334-0KE00-7AB0 6AG1314-6EH04-7AB0
6AG1313-6CG04-7AB0 6AG1331-7RD00-2AB0 6AG1322-1BF01-2XB0
6AG1322-1FH00-7AA0 6AG1315-2EH14-2AY0 6AG1317-2EK14-2AY0
6AG1332-5HF00-2AB0 6AG1321-1FF01-2AA0 6AG1331-7PF11-4AB0
6AG1313-5BG04-2AY0 6AG1321-7BH01-4AS0 6AG1340-1AH02-2AE0
6AG1315-2AH14-7AB0 6AG1332-5HD01-7AB0 6AG1340-1CH02-2AE0
6AG1314-6BH04-7AB0


联系我们
E-mail:info@fitsitech.com  手机:19928764188 联系人:明经理
地址:深圳市龙华区龙华街道清华社区龙观东路57号尚美时代

     
咨询
姓 名:
邮件:
描述:
CopyRight © 2010~2017 深圳市菲特思科技有限公司 版权所有.     网站地图    粤ICP备14001694号-由万创科技提供技术支持   
展开
  • QQ咨询

官方二维码