SIMATIC S7-200 SMART, Digital I/O SM DR32, 16DI/16DO, 16 DI 24 V DC, Sink/Source, 16 DO, relay 2 A

订购码:
General information
Product type designation SM DR32, DI 16x24 V DC, DQ 16x relay/2A
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC)
28.8 V
Input current
Current consumption, typ. 165 mA; Current for 24 V DC input power
165 mA; For 5 V DC from CPU module
from backplane bus 5 V DC, typ.
Digital inputs
Number of digital inputs
● in groups of
16
2
Parallel switching of inputs Yes
Input characteristic curve in accordance with IEC 61131, type 1  Yes
Number of simultaneously controllable inputs
horizontal installation
— up to 50 °C, max. 16
vertical installation
— up to 40 °C, max. 16
Input voltage
● Type of input voltage
● Rated value (DC)
● for signal "0"
● for signal "1"
DC
24 V
< 5 V DC
+15 to +30 V
Input current
● for signal "0", max. (permissible quiescent current)
● for signal "1", min.
● for signal "1", max.
● for signal "1", typ.
1 mA
2.5 mA
5 mA 
4 mA
Input delay (for rated value of input voltage)
for standard inputs
— at "0" to "1", max.
— at "1" to "0", max.
200 µs
200 µs
Cable length
● shielded, max.
● unshielded, max.
500 m
300 m
Digital outputs
Number of digital outputs 16
Short-circuit protection No
Output current
● for signal "1" rated value 2 A
Output delay with resistive load
● "0" to "1", max.
● "1" to "0", max.
10 ms
10 ms
Relay outputs
● Number of relay outputs
● Rated supply voltage of relay coil L+ (DC)
— Reverse polarity protection
● Current consumption of relays (coil current of all relays), max.
16
24 V
Yes
165 mA
Switching capacity of contacts
— with inductive load, max.
— on lamp load, max.
— with resistive load, up to 50 °C, max.
— with resistive load, up to 60 °C, max.
— with resistive load, max.
— Thermal continuous current, max.
2 A
30 W; 30 W with DC, 200 W with AC
2 A
2 A
2 A
2 A
Cable length
● shielded, max.
● unshielded, max.
500 m
150 m
Interrupts/diagnostics/status information
Diagnostics indication LED
● for status of the inputs
● for status of the outputs
Yes
Yes
Potential separation
Potential separation digital inputs
● between the channels Yes; Optocoupler
Potential separation digital outputs
● between the channels Yes; Relay, dry contact
Isolation
Isolation tested with 500 V AC for 1 minute for input isolation; 1500 V AC for 1 minute for output isolation
EMC
Interference immunity against discharge of static electricity
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2
— Test voltage at air discharge
— Test voltage at contact discharge
Yes; ±4 kV contact discharge (to IEC 801-2/IEC 1000-4-2; ESD), ±8 kV air discharge (to IEC 801-2/IEC 1000-4-2; ESD)
8 kV
4 kV
Interference immunity against high-frequency electromagnetic fields
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-3
— Frequency range of the RF radiation
Yes
80 to 1000 MHz, 10 V/m, 1.4 to 2.0 GHz, 3 V/m, 2.0 to 2.7 GHz, 1
V/m(In the range of 87 MHz to 187 MHz, 174 MHz to 230 MHz and 470 MHz to 790 MHz: 3V/m )
Interference immunity to cable-borne interference
● Interference immunity on supply lines acc. to IEC 61000-4-4
● Interference immunity on signal cables acc. to IEC 61000-4-4
Yes; 2 kV acc. to IEC 61000-4-4, burst

Yes; ±2 kV acc. to IEC 61000-4-4, Burst
Interference immunity against voltage surge
● Interference immunity on supply lines acc. to IEC 61000-4-5
● asymmetric interference
— Test voltage on supply cables
— Test voltage on signal cables >30m
Yes; With upstream protective element


2 kV
2 kV
Interference immunity against conducted variable disturbance induced by high-frequency fields
● Interference immunity against high frequency current feed acc. to IEC 61000-4-6
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6
Yes
Yes; 10 V/m, with 80% amplitude modulation at 1 kHz
— Test voltage at 80% amplitude modulation with 1kHz in the range 9 kHz to 80 MHz 10 V
Emission of radio interference acc. to EN 55 011
● Emission of radio interference
● Limit class A, for use in industrial areas
Interference emission to EN 50081-2, testing to EN 55011, Class A, Group 1
Yes
Degree and class of protection
IP degree of protection IP20
Standards, approvals, certificates
CE mark Yes
Dimensions
Width 70 mm
Height 100 mm
Depth 81 mm
Weights
Weight, approx. 295.4 g


标记:
6ES7288-3AQ04-0AA0 6ES7288-3AT04-0AA0 6ES7288-2DE08-0AA0
6ES7288-2DT32-0AA0 6ES7288-2DR32-0AA0 6ES7288-3AE04-0AA0
6ES7288-3AQ02-0AA0 6ES7288-2DT08-0AA0 6ES7288-3AR04-0AA0
6ES7288-3AE08-0AA0 6ES7288-3AM03-0AA0 6ES7288-3AM06-0AA0
6ES7288-2DT16-0AA0 6ES7288-3AR02-0AA0 6ES7288-2DR16-0AA0
6ES7288-2DR08-0AA0


联系我们
E-mail:info@fitsitech.com  手机:19928764188 联系人:明经理
地址:深圳市龙华区龙华街道清华社区龙观东路57号尚美时代

     
咨询
姓 名:
邮件:
描述:
CopyRight © 2010~2017 深圳市菲特思科技有限公司 版权所有.     网站地图    粤ICP备14001694号-由万创科技提供技术支持   
展开
  • QQ咨询

官方二维码